5.10 Overtravel and Related Settings
5.10.5 Overtravel Release Method Selection
5-30
5.10.5
Overtravel Release Method Selection
You can set Pn022 = n.
X (Overtravel Release Method Selection) to release overtravel.
Internal limit active
(bit 11) in
statusword
changes to 1 during overtravel. The motor will not be
driven if there is overtravel in the same direction as the reference.
*
Here, “separated” means a position that is further in the positive direction than the P-OT signal or a position that
is further in the negative direction than the N-OT signal.
When Pn022 Is Set to n.
0
When Pn022 Is Set to n.
1
Parameter
Meaning
When
Enabled
Classification
Pn022
(2022
hex)
n.
0
(default setting)
Overtravel exists while the P-OT or N-OT signal is
being input.
After restart
Setup
n.
1
Overtravel exists while the P-OT or N-OT signal is
input and the current position of the workpiece is
separated
*
from the P-OT signal or N-OT signal.
Machine
coordinate
-2
-1
0
1
2
P-OT signal
N-OT signal
Statusword
(6041 hex bit11)
Motor status
Inactive
Active
Inactive
Inactive
Active
Inactive
0
0
0
1
1
Normal operation
Only forward
operation
Normal
operation
Only reverse
operation
Normal operation
Machine
coordinate
P-OT signal
N-OT signal
Statusword
(6041 hex bit11)
Motor status
-2
-1
0
1
2
Inactive
Active
Inactive
Inactive
Active
Inactive
1
0
1
Normal operation
Only forward
operation
Only reverse
operation