![background image](http://html.mh-extra.com/html/yaskawa/jusp-ns115/jusp-ns115_user-manual_907076193.webp)
9 Troubleshooting
9-18
A.EA
A.EA: An Error which occurs when the SERVOPACK is used with the NS115.
Display and Outputs
Note: OFF: Output transistor is OFF (alarm state). ON: Output transistor is
ON.
Status and Remedy for Alarm
A.EB
A.EB: SERVOPACK Initial Access Error
Display and Outputs
Note: OFF: Output transistor is OFF (alarm state). ON: Output transistor is
ON.
Status and Remedy for Alarm
Alarm Outputs
Alarm Code Outputs
ALM Output
ALO1
ALO2
ALO3
OFF
ON
ON
OFF
Cause
Remedy
A
SERVOPACK is defective.
Replace the SERVOPACK.
B
A software version of SERVOPACK is less
than 33.
Replace the SERVOPACK. (A software
version is more than 33.)
C
S is connected.
Disconnect the S.
Alarm Outputs
Alarm Code Outputs
ALM Output
ALO1
ALO2
ALO3
OFF
ON
ON
OFF
Cause
Remedy
A
SERVOPACK is defective.
Replace the SERVOPACK.
At power ON
A
At power ON
A