![YASKAWA JUSP-NS115 User Manual Download Page 224](http://html.mh-extra.com/html/yaskawa/jusp-ns115/jusp-ns115_user-manual_907076224.webp)
Appendix B List of Parameters
B-6
* 1. Parameter changing method is as follows:
: Can be changed at any time, and immediately enabled after changing. (Called an online
parameter.)
{
: Can be changed when DEN = 1. Immediately enabled after changing. Do not change
when DEN = 0. Doing so may lead to misoperation, such as position errors. (Called an
online parameter.)
∆
: Can be changed at any time, and enabled immediately after the power is turned OFF then
ON again. Sends a Set Up Device command at power-ON when changing a parameter.
(Called an offline parameter.)
−
: Do not access.
* 2. When using an External Regenerative Resistor, set the capacity of the regenerative resistor.
Sequence-
related
Parameters
Pn508
Timing for Brake Reference Output during
Motor Operation
2
10ms
10 to 100
50
Pn509
Momentary Hold Time
2
ms
20 to 1000
20
Pn50A
Input Signal Selections 1
2
−
0000H to
FFFFH
2881H
∆
Pn50B
Input Signal Selections 2
2
−
0000H to
FFFFH
6583H
∆
Pn50C
Reserved by system
2
−
−
8888H
−
Pn50D
Reserved by system
2
−
−
8888H
−
Pn50E
Output Signal Selections 1
2
−
0000H to
3333H
3211H
∆
Pn50F
Output Signal Selections 2
2
−
0000H to
3333H
0000H
∆
Pn510
Output Signal Selections 3
2
−
0000H to
0033H
0000H
∆
Pn511
Input Signal Selections 3
2
−
0000H to
FFFFH
8888H
∆
Pn512
Output Signal Reversal
2
−
0000H to
0111H
0000H
∆
For Rotary
Motor Only
Pn51A
Error Level between Motor and Load
Position
2
pulse
1 to 32767
10
Sequence-
related
Parameters
Pn51E
Position Error Over Warning Detection
Level
2
%
0 to 100
100
For Linear
Motor Only
Pn580
Zero Clamp Level
2
mm/s
0 to 5000
10
For Linear
Motor Only
Pn581
Rotation Detection Level
2
mm/s
1 to 5000
20
For Linear
Motor Only
Pn582
Speed Coincidence Signal Output Width
2
mm/s
0 to 100
10
For Linear
Motor Only
Pn583
Brake Reference Output Speed Level
2
mm/s
0 to 5000
100
Sequence-
related
Parameters
Pn600
Regenerative Resistor Capacity
*2
2
10W
0 to 1000
0
Pn601
Reserved by system
2
−
−
0
−
Table B.1 Parameter List (cont’d)
Category
Pn No.
Name
Size
Unit
Setting
Range
SGDH
Factory
Setting
Changing
Method
*1