![YASKAWA JUSP-NS115 User Manual Download Page 59](http://html.mh-extra.com/html/yaskawa/jusp-ns115/jusp-ns115_user-manual_907076059.webp)
4.3 Main Commands
4-15
4
4.3.8
Start Synchronous Communications (SYNC_SET: 0DH)
Byte
SYNC_SET
Description
Command
Response
1
0DH
0DH
Processing
classifications
Network com-
mand group
Synchronization
classifications
Asynchronous
2
ALARM
Processing time
Transmission
cycle or more
Subcommand
Cannot be used.
3
STATUS
• Starts synchronous communications. Switches from phase 2 to phase 3.
• Processing is completed at the WDT changing edge.
However, if WDT errors are being masked by parameter Pn800.0, processing
is completed when this command is received.
• During phase 1, a MECHATROLINK-II command warning (A.95) will occur
and the command will be ignored.
• During phase 3, the command will be ignored (without a warning).
• The SERVOPACK will change to Servo OFF if this command is received
when the SERVOPACK is Servo ON during phase 2.
• The synchronous communications have to be restarted using this command
when the MECHATROLINK-II communications error (A.E6) or the
MECHATROLINK-II synchronization error (A.E5) occurs.
4
5
6
7
8
9
10
11
12
13
14
15
16
WDT
RWDT