![YASKAWA JUSP-NS115 User Manual Download Page 48](http://html.mh-extra.com/html/yaskawa/jusp-ns115/jusp-ns115_user-manual_907076048.webp)
4 MECHATROLINK-
II
Communications
4.2.1 Communications Settings
4-4
4.2
Switches for MECHATROLINK-
II
Communications Settings
This section describes the switch settings necessary for MECHATROLINK-II communications.
4.2.1
Communications Settings
The SW2 DIP switch sets the MECHATROLINK-II
communications settings, as shown below. Settings that have
been changed are enabled when the power is turned OFF and
ON.
1. When connecting to a MECHATROLINK network, set bits 1 and 2 to OFF.
2. Baud rate: 4 Mbps, transmission bytes: 30 (bit 1 = OFF, bit 2 = ON) cannot be used.
SW2
Item
Setting
Description
Factory
Setting
Bit 1
Baud rate
OFF
4 Mbps
ON
ON
10 Mbps
Bit 2
Transmission
bytes
OFF
17 bytes
ON
ON
30 bytes
Bit 3
Station address
OFF
Station address =
40H+SW1
OFF
ON
Station address =
50H+SW1
Bit 4
Reserved
OFF
-
OFF
ON
OFF
SW2 (factory setting)
1
2
3
4
1
2
3
4
5
6
7 8 9
A
B
C
D
E
F
0
SW1 (factory setting)
IMPORTANT