![YASKAWA JUSP-NS115 User Manual Download Page 181](http://html.mh-extra.com/html/yaskawa/jusp-ns115/jusp-ns115_user-manual_907076181.webp)
9 Troubleshooting
9-6
A.83
A.83: Encoder Battery Error
Display and Outputs
Note: OFF: Output transistor is OFF (alarm state).
Status and Remedy for Alarm
Note: No alarm will occur at the SERVOPACK if the battery error occurs
during operation.
Alarm Outputs
Alarm Code Outputs
ALM Output
ALO1
ALO2
ALO3
OFF
OFF
OFF
OFF
Cause
Remedy
A
• Battery is not connected.
• Battery connection is defective.
Check and correct battery connection.
B
Battery voltage is below specified value.
Specified value: 2.7 V.
Install a new battery while the control
power to SERVOPACK is ON. After
replacement, turn ON the power again.
C
Circuit board (1PWB) is defective.
Replace the servomotor.
At power ON
Pn002.2 = 0
Pn002.2 = 1
A, B, C
C
At SENS_ON command
C