![YASKAWA JUSP-NS115 User Manual Download Page 54](http://html.mh-extra.com/html/yaskawa/jusp-ns115/jusp-ns115_user-manual_907076054.webp)
4 MECHATROLINK-
II
Communications
4.3.3 Write Parameter (PRM_WR: 02H)
4-10
4.3.3
Write Parameter (PRM_WR: 02H)
Byte
PRM_WR
Description
Command
Response
1
02H
02H
Processing
classifications
Data communica-
tions command
group
Synchronization
classifications
Asynchronous
2
ALARM
Processing time
Refer to the fol-
lowing description
Subcommand
Cannot be used.
3
STATUS
• Temporarily writes parameters and does not store them in E
2
PROM memory.
Offline parameters are enabled with the Set Up Device command (CONFIG)
after setting.
• Can be used during phases 2 and 3.
• A warning will occur and the command will be ignored in the following cases.
- During phases other than phases 2 and 3:
MECHATROLINK-II command warning (A.95)
- If a digital operator is connected: MECHATROLINK-II command warning
(A.95)
- If SigmaWin and so on are connected: MECHATROLINK-II command
warning (A.95)
- If NO is not within range: Parameter setting warning (A.94)
- If SIZE does not match: Parameter setting warning (A.94)
- If PARAMETER is not within range or would result in a calculation over-
flow: Parameter setting warning (A.94)
• If communications are in progress with a Digital Operator, a command execu-
tion incomplete alarm (A.ED) may occur.
• For details on NO, SIZE, and PARAMETER, refer to
Appendix B List of
Parameters
.
• Processing time
- 1 ms when writing NS115 parameter
- 4 to 6 ms when writing SGDH SERVOPACK parameter
4
5
NO
NO
6
7
SIZE
SIZE
8
PARAMETER
PARAMETER
9
10
11
12
13
14
15
16
WDT
RWDT