STARTER MOTOR
10-8
6LPA Service Manual
Starter
© 2007 Yanmar Marine International
Starter Inspection and Testing
Armature
1. Using an ohmmeter (Figure 10-10, (1)) check
the commutator for continuity between the
commutator segments. If segments are
electrically open, replace the armature.
Figure 10-10
Figure 10-10
2. Using an ohmmeter (Figure 10-11, (1)) check
the commutator for continuity between the
commutator and armature coil. If electrical
continuity is measured, replace the armature.
Figure 10-11
Figure 10-11
3. Inspect the commutator surface for damage,
dirt and burning. If the commutator surface is
lightly damaged, imperfections may be
corrected with #400 emery cloth or by turning
on a lathe.
4. Inspect the commutator for radial runout by
mounting the commutator on a V-block to
measure runout using a dial indicator
(Figure 10-12).
Commutator radial runout:
• Maximum: 0.05 mm (0.001 in.)
Figure 10-12
Figure 10-12
5. If the measured value exceeds the specified
maximum, correct using a lathe if possible or
replace the armature.
6. Measure commutator diameter using calipers
(Figure 10-13). If the measured value is less
than the specified minimum, replace the
armature.
Commutator diameter:
• Standard 36.0 mm (1.41 in.)
• Minimum 35.0 mm (1.37 in.)