STARTER MOTOR
10-14
6LPA Service Manual
Starter
© 2007 Yanmar Marine International
Magnetic Switch
1. Using an ohmmeter (Figure 10-31, (1)) check
the continuity of the pull-in coil circuit between
terminals 50 (Figure 10-31, (2)) and C
(Figure 10-31, (3)). If no electrical continuity is
measured, replace the magnetic switch.
Figure 10-31
Figure 10-31
2. Using an ohmmeter (Figure 10-32, (1)) check
the continuity between terminals 50
(Figure 10-32, (2)) and the switch body
(Figure 10-32, (3)). If no electrical continuity is
measured, replace the magnetic switch.
Figure 10-32
Figure 10-32
Starter Reassembly
1. Apply grease to the armature bearing and
install the armature in the field frame
(Figure 10-33).
Note: Use high-temperature grease for
lubrication of the bearing and gear when
reassembling the starter.
Figure 10-33
Figure 10-33
2. Install the brush holder to the armature.
3. Install the brush to the brush holder while
securing the rear of the brush spring with a
screwdriver (Figure 10-34). Connect all four
brushes in the same manner.
NOTICE: Make sure that the positive (+) lead
wire is not grounded.
Figure 10-34
Figure 10-34
4. Install the end cover to the field coil frame using
two screws (Figure 10-35, (1)).
(2)
(1)
0005419
(
3
)
0005420
(2)
(
3
)
(1)
0005421
0005422