Checking the condition of the bulb sockets
The following procedure applies to all of the bulb
sockets.
1. Check:
• Bulb socket (for continuity)
(with the multimeter)
No continuity
→
Replace.
Check each bulb socket for continuity in the
same manner as described in the bulb section;
however, note the following.
a. Install a good bulb into the bulb socket.
b. Connect the multimeter probes to the re-
spective leads of the bulb socket.
c. Check the bulb socket for continuity. If any of
the readings indicate no continuity, replace
the bulb socket.
CHECKING THE FUSE
To avoid a short circuit, always turn the main
when checking or replacing
1. Remove:
• Seat
Refer to “GENERAL CHASSIS” on page 4-1.
2. Check:
• Fuse
a. Connect the multimeter to the fuse and
check the continuity.
Set the multimeter selector to “Ω × 1”.
b. If the multimeter indicates “
∞
”, replace the
fuse.
3. Replace:
• Blown fuse
a. Set the main switch to “OFF”.
b. Install a new fuse of the correct amperage
rating.
c. Set on the switches to verify if the electrical
circuit is operational.
d. If the fuse immediately blows again, check
the electrical circuit.
Never use a fuse with an amperage rating
other than that specified. Improvising or us-
ing a fuse with the wrong amperage rating
may cause extensive damage to the electri-
cal system, cause the lighting and ignition
systems to malfunction and could possibly
cause a fire.
4. Install:
• Seat
Refer to “GENERAL CHASSIS” on page 4-1
CHECKING AND CHARGING THE BATTERY
Batteries generate explosive hydrogen gas
and contain electrolyte which is made of poi-
sonous and highly caustic sulfuric acid.
Therefore, always follow these preventive
measures:
• Wear protective eye gear when handling or
working near batteries.
• Charge batteries in a well-ventilated area.
• Keep batteries away from fire, sparks or
open flames (e.g., welding equipment,
lighted cigarettes).
• DO NOT SMOKE when charging or han-
dling batteries.
• KEEP BATTERIES AND ELECTROLYTE
OUT OF REACH OF CHILDREN.
• Avoid bodily contact with electrolyte as it
can cause severe burns or permanent eye
injury.
FIRST AID IN CASE OF BODILY CONTACT:
EXTERNAL
• Skin — Wash with water.
• Eyes — Flush with water for 15 minutes and
get immediate medical attention.
Multimeter
Item
Amperage
rating
Q’ty
Fuse
20 A
1
ssssssssssssssssssssssssssss
8-62
ELECTRICAL COMPONENTS
INTERNAL
• Drink large quantities of water or milk fol-
lowed with milk of magnesia, beaten egg or
vegetable oil. Get immediate medical atten-
tion.
CAUTION:
• This is a sealed battery. Never remove the
sealing caps because the balance between
cells will not be maintained and battery per-
formance will deteriorate.
• Charging time, charging amperage and
charging voltage for an MF battery are dif-
ferent from those of conventional batteries.
The MF battery should be charged accord-
ing to the appropriate charging method. If
the battery is overcharged, the electrolyte
level will drop considerably. Therefore,
take special care when charging the bat-
tery.
NOTE:
Since MF batteries are sealed, it is not possible
to check the charge state of the battery by mea-
suring the specific gravity of the electrolyte.
Therefore, the charge of the battery has to be
checked by measuring the voltage at the battery
terminals.
1. Remove:
• Seat
Refer to “GENERAL CHASSIS” on page 4-1.
2. Disconnect:
• Battery leads
(from the battery terminals)
CAUTION:
First, disconnect the negative battery lead
“1”, and then positive battery lead “2”.
3. Remove:
• Battery
4. Check:
• Battery charge
a. Connect a multimeter to the battery termi-
nals.
NOTE:
• The charge state of an MF battery can be
checked by measuring its open-circuit voltage
(i.e., the voltage when the positive battery ter-
minal is disconnected).
• No charging is necessary when the open-cir-
cuit voltage equals or exceeds 12.8 V.
b. Check the charge of the battery, as shown in
the charts and the following example.
1
2
Positive tester probe
→
positive battery terminal
• Negative tester probe
→
negative battery terminal
Example
Open-circuit voltage = 12.0 V
Charging time = 6.5 hours
Charge of the battery = 20–30%
A. Open-circuit voltage (V)
B. Charging time (hours)
C. Relationship between the open-circuit voltage
and the charging time at 20 °C (68 °F)
D. These values vary with the temperature, the
condition of the battery plates, and the
electrolyte level.
ssssssssssssssssssssssssssss
•
Summary of Contents for YZF-R15
Page 1: ...2008 SERVICE MANUAL YZF R15 20P F8197 E0 ...
Page 33: ...2 14 ELECTRICAL SPECIFICATIONS Coil resistance 54 0 66 0 Fuse 20 0A Ω Fuse ...
Page 46: ...2 27 LUBRICATION POINTS AND LUBRICANT TYPES LUBRICATION DIAGRAMS A 1 2 3 4 5 6 7 ...
Page 48: ...2 29 LUBRICATION POINTS AND LUBRICANT TYPES 1 2 3 4 ...
Page 49: ...2 30 LUBRICATION POINTS AND LUBRICANT TYPES 1 Camshaft 2 Crankshaft 3 Main axle 4 Drive axle ...
Page 50: ...2 31 COOLING SYSTEM DIAGRAMS COOLING SYSTEM DIAGRAMS 1 2 3 4 1 5 7 6 4 ...
Page 52: ...2 33 CABLE ROUTING CABLE ROUTING 1 5 2 3 6 4 8 7 ...
Page 54: ...2 35 CABLE ROUTING A A B B C C A A C C B B A B C 1 2 3 4 5 4 5 6 6 7 8 9 10 11 10 11 12 12 ...
Page 56: ...2 37 CABLE ROUTING 1 2 5 4 3 ...
Page 60: ...2 41 CABLE ROUTING A A B C D E 1 2 3 4 5 6 7 8 9 10 A ...
Page 121: ...4 24 FRONT BRAKE Refer to BLEEDING THE HYDRAULIC BRAKE SYSTEM on page 3 18 ...
Page 249: ...7 8 THROTTLE BODY ...
Page 250: ...7 9 AIR INDUCTION SYSTEM AIR INDUCTION SYSTEM 1 2 5 4 5 6 3 2 1 6 4 3 ...
Page 257: ......
Page 269: ...8 12 CHARGING SYSTEM 1 AC magneto 2 Rectifier regulator 3 Battery 42 Fuse ...
Page 271: ...8 14 CHARGING SYSTEM ...
Page 275: ...8 18 LIGHTING SYSTEM ...
Page 285: ...8 28 COOLING SYSTEM ...
Page 311: ...8 54 FUEL PUMP SYSTEM ...