RS-1600/1602-FC-SBD User Guide
48
Note
“x” = no bearing on these states
Table 4–2
Ops Panel LED States
Ops Panel LEDs
Other Associated
LEDs or Alarm
State Description
Power
(Green)
PSU/
Cooling/
Temp
(Amber)
System
(Amber)
Address
Mode
Error
(Amber)
FC
Loop
Speed
(Green)
Hub
Mode
Selected
(Green)
On
Off
Off
Off
Off
Off
HDD green LEDs
OFF
5V Aux present, overall power failed
On
On
On
On
On
On
single beep, then
double beep
Ops Panel power On (5s) test state
On
Off
Off
Off
x
x
HDD green LEDs
ON
Power On, all functions good
On
On
Off
x
x
x
PSU LEDs or Fan
LEDs
Any PSU fault or Fan fault
On
On
Flash
x
x
x
Over or Under temperature
On
Off
On
x
x
x
ESI LED on SBD
ESI processor module A Failed
On
Off
On
x
x
x
ESI LED on SBD
ESI processor module B Failed
On
Off
On
x
x
x
None
• Unknown (invalid or mixed)
SBD module type installed, or
• I2C Bus Failure (inter ESI
processor), or
• Backplane autostart watchdog
failed.
On
Flashing Flashing
x
x
x
PSU Removed
PSU removed and System power
redundancy check option set. No
indication if option not set.
On
Off
Flashing
x
x
x
SI alarm
No SES Drives fitted
On
Flashing
On
x
x
x
Intermittent
audible alarm
Ops to ESI Communications failed
On
x
x
Flashing
x
x
Invalid address mode setting
(change thumb wheel to valid
ranges)
On
x
x
x
On
x
2Gb/s Drive loop speed selected
On
x
x
x
x
On
RAID ONLY
Host side Hub mode enabled
Summary of Contents for RS-1600-FC-SBD
Page 6: ...vi RS 1600 1602 FC SBD User Guide...
Page 14: ...RS 1600 1602 FC SBD User Guide xiv...
Page 32: ...RS 1600 1602 FC SBD User Guide 18...
Page 47: ...Getting Started 33 Figure 2 15 Connecting Multiple Enclosures...
Page 58: ...RS 1600 1602 FC SBD User Guide 44...