Troubleshooting
45
Chapter 4
Troubleshooting and
Problem Solving
4.1 Overview
RS-1600-FC-SBD and RS-1602-FC-SBD Enclosures include a processor and associated monitoring and
control logic to enable them to diagnose problems within the enclosure’s power, cooling and drive
systems.
The Enclosure Services Processor is housed along with the Ops Panel in the rear of the enclosure.
The sensors for power and cooling conditions are housed within the Power Supply/Cooling modules.
There is independent monitoring for each unit.
If a fault is indicated on the Ops Panel, please refer to
Table 4–2
.
4.1.1 Initial Start-up Problems
4.1.1.1
Faulty Cords
First check that you have wired up the subsystem correctly. Then, if:
• cords are missing or damaged
• plugs are incorrect
• cords are too short
Call your supplier for a replacement.
4.1.1.2
Alarm Sounds On Power Up
Please refer to Section
4.3
.
4.1.1.3
Green “Signal Good” LED on SBD Module Not Lit
Check that the Rx and Tx cables have not been inverted during installation.