Introduction
5
PSU voltage operating ranges are nominally 115V or 230V AC, selected automatically.
.
Four LEDs mounted on the front panel of the Power Supply/Cooling module (see
Figure 2–1
) indicate
the status of the PSU and the fans.
1.3.1.2
-48V DC Power Supply/Cooling Module
A -48V DC Input Power Supply/Cooling Module variant is also available (
Figure 1–6
).
Warning
The -48V DC Power Supply/Cooling module is not an operator removable part. It should only be
removed by a technician who has knowledge of the hazards present within the module.
1.3.1.3
Multiple Power Supply/Cooling Modules
The RS-1600-FC-SBD or RS-1602-FC-SBD must always be operated with two Power Supply/Cooling
modules fitted. The two Power Supply/Cooling modules operate together so that if one fails the other
maintains the power supply and cooling while you replace the faulty unit.
Module replacement should only take a few minutes to perform but must be completed within 10 minutes
from removal of the failed module.
Figure 1–6
-48V DC Power Supply/Cooling Module