RS-1600/1602-FC-SBD User Guide
34
2.8 Drive Enclosure Device Addressing
Each enclosure has 16 drives. The SEL_ID of each drive is determined by the device slot (0-15) in which
it is installed and the address range setting, which is set by means of the Enclosure ID switch, additionally
an Address Mode (Mode 0 or Mode 1) must be selected, please refer to
Table 2–4
.
The Mode selection is set on the Ops Panel (shown in
Figure 1–7 on page 6
) at the rear of the enclosure.
The switch settings are as follows:
Notes
1 ON
= switch to the
Left
,
OFF
= switch to the
Right
.
2
Switches 2 to 6 and 12 are
Not Used
.
3
Modes 2 and 3 are
Not Used.
Table 2–3
Ops Panel Switch Functions (
Default settings for RS-1600-FC-SBD or RS-1602-FC-SBD
SBD module usage at 2Gb/s)
Switch
Number
Function
Recommended Setting Definition
1
Loop Select,
Single (1x16)
On
SBD operated on single loop of 16 drives
Mandatory
2
Not Used
3
Not Used
4
Not Used
5 & 6
Not Used
7 & 8
Drive Loop Speed
Select
Sw7
Sw8
On
Off
Force 2Gb/s
Off
Off
Force 1Gb/s
9 & 10
Drive Addressing
Mode Selection
Sw9
Sw10
On
On
Mode 0
Off
On
Mode 1
11
SOFT SELECT
On
Select functions using the hardware
switches
12
Not Used