Getting Started
19
Chapter 2
Getting Started
2.1 Introduction
In this chapter, you are shown how to install your RS-1600-FC-SBD or RS-1602-FC-SBD Enclosure and
plug-in modules into an industry standard 19 inch rack cabinet.
Caution
When connecting up the RS-1600-FC-SBD or RS-1602-FC-SBD subsystem, use only the power cords
supplied or cords which match the specification quoted in section
1.5.6
.
2.2 Planning Your Installation
Before you begin installation you should become familiar with the configuration requirements of your RS-
1600-FC-SBD or RS-1602-FC-SBD subsystem, detailed in
Figure 2–1
. The correct positions of each of
the optional plug-in modules are shown in
Figure 2–1
. Please refer to sections
2.6
-
2.5
for details of SBD
module configurations and installation.
Caution
Dummy Carriers and Blank Modules MUST be fitted to ALL unused bays, there will be inadequate drive
cooling if any are left open.
Table 2–1
Enclosure Subsystem Configuration
Module
Location
Drive Bays
ALL drive bays must be fitted with either a drive carrier module or a dummy
carrier, no bays should be left completely empty.
Power Supply/Cooling
Modules
Two Power Supply/Cooling modules must be fitted. Full power and cooling
redundancy is provided while a faulty module is replaced. Install the Power
Supply/Cooling modules in rear Bays 1 & 5.
Note:
Rear bays are numbered from 1 to 5 commencing from the right
hand side)
SBD Module
Install in rear Bays 3 and 4
Ops Panel
(integral part of chassis assembly) Installed in rear Bay 2