RS-1600/1602-FC-SBD User Guide
16
1.5.9 SBD Module Specification
FC-AL: Error Handling
Auto disk Port Bypass on:
• CRC error level exceeding 10 errors per 512 million frames persistently.
• Word error levels exceeded
–
BURST - more than 400 errors in a 4 second.period, 3 times consecutively.
–
Long term- more than 20 errors in a30 minute period consecutively.
• Clock Delta greater than 200 ppm.
• Repeated insertion.
• Failure to insert within a minute.
For more details on the algorithms used and how to configure these settings please contact your
customer service representative.
SES Reporting
Using vendor specific Extended Pages the following information can be gathered:
• Bypass reason, specific reason why the port is not inserted.
• Word errors
• CRC errors
• Clock delta
• Loop Up
• insert
• stalls
• utilization
Speed
1Gb/s or 2Gb/s FC-AL
• Creates connections to a single logical loop of 16 drives
Mounting
Rear, single bays 3 and/or 4
(see
Figure 1–3
)
Connectors
• 4 x SFP connectors for Host/Expansion Ports, to accommodate the
following interconnects:
a
optical (LC to LC cable), maximum length 500m
b
copper (100 ohm SFP patch cable) maximum length 1.5m, or
c
copper SFP, maximum length 10m.
• 1 x RS232 , 6 pin Mini-DIN
(factory use only)
Power Dissipation
5A @ 3.3V, 1A @ 5V