Troubleshooting
55
4.8 Replacing a Module
Warning
Whenever replacing a module NEVER leave an EMPTY space in the rear of the enclosure, obtain
a replacement before removing the problem part.
Please refer to
Chapter 2
, ”Getting Started”
for information on the initial installation of the plug-in modules
in the RS-1600-FC-SBD or RS-1602-FC-SBD enclosure.
Warning
Observe all conventional ESD precautions when handling RS-1600-FC-SBD or RS-1602-FC-SBD
modules and components. Avoid contact with Backplane components and module connectors,
etc.
4.8.1 Power Supply/Cooling Modules
Warning
Do not remove covers from the Power Supply/Cooling (PSU) module. Danger of electric shock
inside. Return the PSU to your supplier for repair.
4.8.1.1
Removing an AC Power Supply/Cooling Module
Warning
Do not remove the faulty Power Supply/Cooling module unless you have a replacement unit of the
correct type ready for insertion.
If a power supply unit or its fan is faulty, you must replace the whole Power Supply/Cooling module.
As there should always be two power supply units installed, you can continue working while replacing the
faulty module.
1
Make sure you identify the faulty Power Supply/Cooling module correctly, from the two modules installed.
2
Switch off and disconnect the power supply cord.
3
Squeeze the two latches on the PSU handle together (
Figure 4–3
) and open the handle to cam the PSU
out of the enclosure (
Figure 4–4
).
4
Grip the handle and withdraw the PSU (
Figure 4–5
).
4.8.1.2
Inserting the Module
1
Check for damage, especially to the rear connector on the PSU.
Caution
Handle the module carefully and avoid damaging the connector pins. Do not install the module if any pins
appear to be bent.
2
With the PSU handle (
Figure 4–4
) in the open position, slide the module into the enclosure.
Important
install the Power Supply/Cooling module in the right hand bay (Rear Bay 1) of the enclosure in an
“upside down* orientation.
3
Cam the module home by manually closing the PSU handle (see
Figure 4–5
). A click should be heard as
the handle latches engage (see
Figure 4–3
).
4
Connect the power supply cord to the power source and switch the power supply ON.
Note
The alarm will sound until the new Power Supply/Cooling module is operating correctly.
Summary of Contents for RS-1600-FC-SBD