RS-1600/1602-FC-SBD User Guide
32
Important
Optical modules must be UL (or other North American NRTL) RECOGNISED COMPONENT and the
laser in the module must comply with Laser Class 1, US 21 CFR (J) and EN 60825-1.
Please contact your supplier for a list of qualified optical SFP components.
If passive copper cables are connected, the cable must not have a connection to a common
ground/earth point.
Note
A maximum of 6 expansion enclosures in Mode 0, or 5 expansion enclosures in Mode 1, can be attached
to RS-1600-FC-SBD or RS-1602-FC-SBD enclosures. A typical expansion configuration is shown in
Figure 2–15
.
Setting the FC-AL Enclosure ID Range
Set each enclosure in a physical loop to a different range.
Drive bay 4/4 is set for immediate start, all other bays are delayed spin start (12 seconds x Module 8 of
the SEL_ID) unless there are two active PSUs when they all start immediately.
Table 2–2
SBD Module LEDs
LED
Color
Description
Host port 0
Signal Good
Green
When ON this LED denotes that incoming FC signal is GOOD.
Host Port 1
Signal Good
Green
When ON this LED denotes that incoming FC signal is GOOD.
Host Port 2
Signal Good
Green
When ON this LED denotes that incoming FC signal is GOOD.
Host port 3
Signal Good
Green
When ON this LED denotes that incoming FC signal is GOOD.
Status
Green
OFF
Flashing
All device ports GOOD @ 2Gb/s
All device ports GOOD @ 1Gb/s
Drives bypassed by module,
see drive LED states.
SBD Module Fault
Amber
When ON this LED denotes that the SBD module is FAILED