W i n d o w s N T P r o b l e m s
11-26
❖
X N I C - E N E T / T R I N G C o n f i g u r a t i o n G u i d e
A General Protection
error occurs in
CorelDraw! when
printing.
CorelDraw! does not accept the
string of the Printer Port as
PASSTHRU.
Change the printer service to the printers
model number using the following
commands:
1. Open a telnet session from a DOS
prompt:
telnet print_server_ip_address 2048
2. Logon to the XNIC as privileged user:
Enter user name or help> su
Server> su
Password> system
3. Enter the following server command:
CHANGE SERVICE LPD PORT 1 DISABLE
This effectively configures the physical
port on the default lpd service as
NONE, which allows redirecting
of the LPD service to other service
records.
4. Define a new service for lpd printer
queue (Queue_Name), assign a new
TCP Port number (TCP Port), and assign
a physical port (n). By default, no
filtering is performed on the data
stream (PASSTHRU). If carriage return
insertion is desired as for text data,
enable the filter parameter.
CHANGE SERVICE Queue_Name
TCP_Port [FILTER ENABLED]
TELNET DISABLED PORT n
On the Windows NT host, the new
printer queue is referenced by the
service name; that is, the -p
argument in the lpr command would
be set to the service name
(Queue_Name).
Table 11.6 Windows NT Problems
(continued)
Problem
Possible Causes
Corrective Actions
ETR-CH11 Page 26 Thursday, October 24, 1996 7:14 AM