DOCUPRINT 4050, 4090, 4850, 4890, AND 92C IPS MESSAGES
XEROX DOCUPRINT IPS MESSAGES GUIDE
3-35
J334
Patch generator intensity at maximum.
The patch generator intensity is above the required parameters.
Action
Press the [Continue] button. If the error persists, contact your service
representative.
J342
CAD loss at limit.
The voltage difference between ESV1 and the developer housing
bias reached the acceptable range and the charge dicorotron shield
voltage cannot be increased.
Action
Press the [Continue] button. If the error persists, contact your service
representative.
J343
Charge shield voltage at maximum.
The charge shield voltage is above the required parameters.
Action
Press the [Continue] button. If the error persists, contact your service
representative.
L020
FOR or BFR failed Memory/Communication.
The FOR or BFR memory communications failed. You can send
output to the dual stacker top tray only. This message displays only
when the stacker is selected.
Action
Specify tray 1 for the output and press the [Continue] button. (Refer
to the
Xerox DocuPrint 4850/4890
or
92C IPS Guide to Configuring
and Managing the System
for the procedure.)
L034
Fuser fallen below preset temperature.
The temperature of the fuser has fallen at least 35 degrees below the
required parameters.
Action
Press the [Continue] button. If the error persists, contact your service
representative.
L035
IOT in power saver mode.
The printer is in power saver mode.
Action
Press the [Continue] button.
L044
Top tray capacity reached.
The top tray is full.
Action
Remove the output from the top tray and press the [Continue] button.