DOCUPRINT 4050, 4090, 4850, 4890, AND 92C IPS MESSAGES
3-38
XEROX DOCUPRINT IPS MESSAGES GUIDE
P022
ADIO terminated communication/other.
The ADIO board terminated due to a communications failure with the
core board or an ADIO board communication error. Diagnostic LEDs
on the ADIO distinguish the type of failure that occurred.
Action
No action is required. If the error persists, contact your service
representative.
P027
GWR Core 8085 lost communication with 8751.
A communication error occurred.
Action
No action is required. If the error persists, contact your service
representative.
P187
Polygon motor not up to speed in 30 sec.
The polygon motor speed is incorrect.
Action
No action is required. If the error persists, contact your service
representative.
P189
EOS connector fault.
The EOS cable assembly is not connected or the 5 volt power supply
is missing on the EOS detector board assembly.
Action
No action is required. If the error persists, contact your service
representative.
P190
SOS connector fault.
The SOS cable assembly is not connected or the 5 volt power supply
is missing on the SOS detector board assembly.
Action
No action is required. If the error persists, contact your service
representative.
P192
ROS LV power supply out of range.
The power supply to the ROS LV is not within the acceptable limits.
Action
No action is required. If the error persists, contact your service
representative.
P193
Power to pixel board out of range.
The pixel clock + 15V, -15V, or the -5.2 V voltage is not within the
acceptable range.
Action
No action is required. If the error persists, contact your service
representative.