DOCUPRINT 96/4635/180 IPS MESSAGES
XEROX DOCUPRINT IPS MESSAGES GUIDE
2-45
10-205
Machine over voltage.
The voltage to the fuser is greater than 256 VAC.
Action
Contact your service representative.
10-206
Fuser transient undertemp.
The temperature of the fuser has fallen at least 35 degrees below the
required parameters.
Action
Press the [Continue] button. If the error persists, contact your service
representative.
10-210
Metering roll undertemp fault.
The temperature of the metering roll did not reach 250 degrees F
within seven minute of startup, or the temperature has dropped
below 250 degrees F during printing. This error is logged by the
system.
Action
No action is required.
10-211
Metering roll overtemp fault.
The temperature of the metering roll has risen above the acceptable
parameters (380 degrees F).
Action
No action is required. If the error persists, contact your service
representative.
10-212
Fuser pressure roll cam in fault.
The Cam-In sensor was unblocked during printing.
Action
Open the front doors of the printer, clear areas 4, 5, 6, and 7, close
the doors, and retry the operation. (Refer to the
Xerox DocuPrint 96/
4635/180 IPS Troubleshooting Guide
for the procedure.)
10-213
Fuser roll failed to cam out.
The Cam-Out sensor was unblocked during cycle down.
Action
Press the [Reset] button located behind the printer control console
front pull-down cover. Open and close the fuser drawer.
10-214
Fuser brake failed while camming in.
The camming motor did not stop during printing.
Action
Open the front doors of the printer, clear areas 4, 5, 6, and 7, close
the doors, and retry the operation.