Central Office (CO) Line Installation
The system connects to the telephone company lines using a two-wire (single pair) cable,
connected to a RJ11 or RJ21X, then connected to the built in MDF Patch Panel on the
motherboard.
Surge Protection Considerations
Transitory voltage spikes, if induced onto CO lines, can travel through the cable and into
the common equipment. The telephone company offers basic protection against this condi-
tion, but it is usually designed to protect the CO circuits and should, therefore, not be
relied upon for total protection. To help protect the system from external voltage surges,
the manufacturer recommends that gas discharge tubes, or similar primary protection
devices, be installed and properly grounded on all lines.
Adding a Music Source
A music source can be connected to the MOH/BGM (External Music) port using the sup-
plied 3.5 mm connector.
Wiring
and
Connectors
Maximum Cable Length
TABLE 4.1
Digital and Door Phone Extension Wiring
26 AWG
650 Ft.
24 AWG
1133 Ft.
22 AWG
1586 ft.
TABLE 4.2
Single Line Telephone Extension Wiring
26 AWG
850 Ft.
24 AWG
1416 Ft.
22 AWG
1983 ft.
Summary of Contents for 45P
Page 1: ...45p Installation Maintenance Manual...
Page 14: ...Introduction 14 XBLUE Networks 1 Related Documents...
Page 38: ...Installation 38 XBLUE Networks Initialization Procedure 4...
Page 116: ...Telephone Operation 116 XBLUE Networks Warning Tone CO Line Call Limiter 5...
Page 138: ...CO Line 138 XBLUE Networks Privacy Rls 6 2...
Page 183: ...XBLUE Networks 183 Restriction Least Cost Routing 6 5 Notes...
Page 196: ...Control 196 XBLUE Networks System Cold Start 6 6...
Page 220: ...Voice Processing System 220 XBLUE Networks 7 Main Programming Menu General Company Settings...
Page 226: ...Voice Processing System 226 XBLUE Networks 7 Voice Processing Programming Flow...
Page 232: ...232 XBLUE Networks i...
Page 241: ...Part Number 45PIM Copyright 2006 XBLUE Networks LLC...