Installation
30
XBLUE Networks
Module I
nstal
lation
4
Adding an External Page
The External Page Port is designed to recieve an external paging unit (amplifier) to allow
voice paging over external speakers. The amplifier interface should be 600 ohms.
Single Line Telephones or Door Phones
Extensions 36 and 37 found on the Option Module can be programmed as either Single
Line Telephone devices or Door Phones.
Door Sensor
Four security sensors, with a screw ther-
mal interfaces, show when an electronic
sensor device circuit is open, sending an
alert to the programmed extensions and
external telephone numbers.
Door Relay
Four door relays, with screw terminal
interfaces, can be programmed to send
a (programmable) momentary closure
to release electronic door lock device.