146
XBLUE Networks
Oper
ator Code
6.3
Press
next
to advance or
back
to return to the previous subfield.
Operator
Code
MBC - 3-17
The Operator code is definable between 0 and 9 and represents the 1 digit telephone num-
ber for the Operator. By default the operator code is “0”.
Data Range: 0, 9
Factory Setting: 0
Press
chg
to select.
SMDR
Time
MBC - 3-18
This timer determines the number of seconds between the last digit dialed and the start of
the “Talk Time” timer which is reported in SMDR. If this time is not reached before the call
is terminated, the call will not be reported in SMDR.
Data Range: 01—25 seconds
Factory Setting: 10 seconds
Press
chg
to select.
SMDR
Output
MBC - 3-19
This programming parameter is used to select which call types (Incoming Calls and/or Out-
going Calls) will generate an output to the SMDR port. Includes two subfields.
Outgoing Call:
Data Range: Y/N
Factory Setting: Y
Incoming Call:
Summary of Contents for 45P
Page 1: ...45p Installation Maintenance Manual...
Page 14: ...Introduction 14 XBLUE Networks 1 Related Documents...
Page 38: ...Installation 38 XBLUE Networks Initialization Procedure 4...
Page 116: ...Telephone Operation 116 XBLUE Networks Warning Tone CO Line Call Limiter 5...
Page 138: ...CO Line 138 XBLUE Networks Privacy Rls 6 2...
Page 183: ...XBLUE Networks 183 Restriction Least Cost Routing 6 5 Notes...
Page 196: ...Control 196 XBLUE Networks System Cold Start 6 6...
Page 220: ...Voice Processing System 220 XBLUE Networks 7 Main Programming Menu General Company Settings...
Page 226: ...Voice Processing System 226 XBLUE Networks 7 Voice Processing Programming Flow...
Page 232: ...232 XBLUE Networks i...
Page 241: ...Part Number 45PIM Copyright 2006 XBLUE Networks LLC...