Software Version Number
If the engine control system needs the software version number, it will use the
request message PGN 59904. The ProAct will respond to a specific query or a
global query.
PGN 59904 Requested Messages
PGN request received by the ProAct The software version number and address
claimed messages can be requested using the request message.
Message
Update rate:
on request
Data length:
3 bytes
Data page:
0
PDU format:
234 (EA)
PDU specific: destination address (global or specific)
Priority: 6
PGN: 59904
(0xEA00)
Data:
Byte: 1..3
requested data PGN* (byte 3 is msb)
Bytes 4..8
reserved
*Supported PGNs: 65242 (SOFT), 60928 (ACL)
PGN 65242 Software Identification (SOFT) message
The software identification message is provided only upon request. One
identification field is sent.
Message
Update rate:
on request
Data length:
variable, <= 8 bytes
Data page:
0
PDU format:
254
PDU specific: 218
Priority: 6
PGN: 65242
(0xFEDA)
Data:
Byte 1:
Number of Software Identification Fields, SPN 965
Actual value:
1 (will always report 1)
Bytes 2-N:
Software Identification, SPN 234
Data length:
variable, up to 7 bytes
Resolution:
ASCII, 0 offset
Actual value:
varies, see listing below**
Byte N:
Delimiter, SPN 234
Actual value:
42 (0x2A)
Character: *
**Data actual value listing
2.03 for firmware 5418-6507 NEW
2.02 for firmware 5418-6133 NEW