5/12/2017
TECH-538/D.W.O. 23160
Page 8 of 189
Available Enclosure Materials and Options
The ICoT enclosures are designed to offer the best fit in multiple environments. The user can select the
enclosure material that is most suitable for the application:
•
Aluminum (low copper content) – Explosion/Flame Proof (ICoT 6000)
•
Stainless Steel (316) – Explosion proof (ICoT 6000)
•
Stainless Steel (316) – General applications, intrinsically safe (ICoT 5000)
•
Engineering resin - General applications, intrinsically safe (ICoT 5000)
The ICoT also offer different options of manifolds, which make available different flow capacities or CV.
The manifold material can also be in Aluminum or Stainless Steel. (See section 1.7).
The physical dimensions of both enclosure and manifolds are in Appendix G – General Arrangement
Product Certifications and Ratings – ICoT 6400
IECEx FMG 13.0033X
Ex d IIB T5 Gb Ta
-50°C to +85°C; IP66
Ex tb IIIC T100°C Db Ta
-50°C to +85°C; IP66
FM13ATEX0081X
II 2 G Ex d IIB T5 Gb Ta
-50°C to +85°C; IP66
II 2 D Ex tb IIIC T100°C Db Ta
-50°C to +85°C; IP66
FM Project ID: 3047816
XP/ I /1/ CD/ T5 Ta -50°C to +85°C;
DIP/ II, III/ 1/ EFG T5 Ta -50°C to +85°C;
I/ 1/ AEx d IIB/ T5 Ta -50°C to +85°C;
21/ AEx tb IIIC/ T100°C Ta -50°C to +85°C;
Type 4X, IP65/IP66
NCC 16.0138 X
Ex d IIC T6 Gb
-20°C
≤ Ta ≤
+40°C