0
Quick Reference of Parameters, Alarms and Faults
CFW501 | 0-13
0
Param.
Function
Adjustable Range
Factory Setting
User
Setting Propr.
Groups Pag.
P0690 Logical Status 2
Bit 0....3 = Not Used
Bit 4 = Force Low Fs
Bit 5 = Sleep State
Bit 6 = Deceleration Ramp
Bit 7 = Acceleration Ramp
Bit 8 = Freeze Ramp
Bit 9 = Setpoint Ok
Bit 10 = DC Link Regulation
Bit 11 = 50Hz Config
Bit 12 = Ride Through
Bit 13 = Flying Start
Bit 14 = DC-Braking
Bit 15 = PWM
ro
READ,
NET
P0695 DOx Value
Bit 0 = DO1
Bit 1 = DO2
Bit 2 = DO3
Bit 3 = DO4
Bit 4 = DO5
ro
NET
P0696 AOx Value 1
-32768 to 32767
ro
NET
P0697 AOx Value 2
-32768 to 32767
ro
NET
P0698 AOx Value 3
-32768 to 32767
ro
NET
P0760 BACnet Dev Inst Hi
0 to 419
0
NET
P0761 BACnet Dev Inst Lo
0 to 9999
0
NET
P0762 Max Number of Master
0 to 127
127
NET
P0763 MS/TP Max info Frame
1 to 65535
1
NET
P0764 I-AM Msg transmition
0 = Power Up
1 = Continuos
0
NET
P0765 Token RX Qtde
0 to 65535
ro
NET
P1000 SoftPLC Status
0 = No Applicative
1 = Installing App.
2 = Incompatible App.
3 = Stopped App.
4 = App. Running
ro
HVAC
P1001 SoftPLC Command
0 = Stop Application
1 = Run Application
2 = Delete Application
1
cfg
HVAC
P1002 Scan Cycle Time
0 to 65535 ms
ro
HVAC
P1003 SoftPLC Application
0 = User
1 = HVAC
1
cfg
HVAC
P1010 HVAC Function Version
0.00 to 100.00
ro
HVAC
P1011 Main PID Aut. Setpoint
-32768 to 32767
0
HVAC
P1012 SoftPLC Parameter 3
-32768 to 32767
0
HVAC
P1013 SoftPLC Parameter 4
-32768 to 32767
0
HVAC
P1014 Main PID Man. Setpoint
0.0 to 100.0 %
0.0 %
HVAC
P1015 Main PID Feedback
-32768 to 32767
ro
HVAC
P1016 Main PID Output
0.0 to 100.0 %
ro
HVAC
P1017 Main PID Action Control
0 = Disable PID
1 = Direct Mode
2 = Reverse Mode
0
cfg
HVAC
P1018 Main PID Operation Mode
0 = Always Automatic
1 = Always Manual
2 = A/M DI w/o bumpless
3 = A/M Net w/o bumpless
4 = A/M DI w/ bumpless
5 = A/M Net w/ bumpless
0
HVAC
P1019 Main PID Sampling Time
0.10 to 60.00 s
0.10 s
HVAC
Summary of Contents for CFW501 V1.8X
Page 2: ......
Page 8: ...Summary...
Page 34: ...General Information 2 4 CFW501 2...
Page 38: ...About the CFW501 3 4 CFW501 3...
Page 42: ...HMI and Basic Programming 4 4 CFW501 4...
Page 58: ...Identification of the Inverter Model and Accessories 6 4 CFW501 6...
Page 72: ...Logical Command and Speed Reference 7 14 CFW501 7...
Page 76: ...Available Motor Control Types 8 4 CFW501 8...
Page 108: ...Functions Common to all the Control Modes 11 14 CFW501 11...
Page 134: ...Digital and Analog Inputs and Outputs 12 26 CFW501 12...
Page 148: ...Faults and Alarms 14 12 CFW501 14...