Digital and Analog Inputs and Outputs
CFW501 | 12-1
12
12 DIGITAL AND ANALOG INPUTS AND OUTPUTS
This section presents the parameters to configure the CFW501 inputs and outputs.
Table 12.1:
I/O Configurations of the CFW501
Functions
Plug-In Module
DI
AI
AO
DOR
DOT
USB
RS-232
RS-485
Sup
10 V
Sup
24 V
4
2
1
2
1
-
-
2
1
1
CFW500-CRS485
DI
– Digital input
DOR
– Relay digital output
AI
– Analog input
AO
– Analog output
DOT
– Transistor digital output
NOTE!
CFW501 HMI shows just the parameters related to the resources available in the plug-in module
connected to the product.
12.1 ANALOG INPUTS
With the analog inputs, it is possible, for instance, to use an external speed reference or to connect a sensor
in order to measure temperature (PTC). Details for those configurations are described in the parameters below.
P0018 – Analog Input Value AI1
P0019 – Analog Input Value AI2
P0020 – Analog Input Value AI3
Adjustable
Range:
-100.0 to 100.0 %
Factory
Setting:
Properties:
ro
Access groups
via HMI:
READ, I/O
Description:
Those read-only parameters indicate the value of the analog inputs AI1, AI2 and AI3 in percentage of the full
scale. The indicated values are those obtained after the offset action and multiplication by the gain. Check the
description of parameters P0230 to P0245.
Summary of Contents for CFW501 V1.8X
Page 2: ......
Page 8: ...Summary...
Page 34: ...General Information 2 4 CFW501 2...
Page 38: ...About the CFW501 3 4 CFW501 3...
Page 42: ...HMI and Basic Programming 4 4 CFW501 4...
Page 58: ...Identification of the Inverter Model and Accessories 6 4 CFW501 6...
Page 72: ...Logical Command and Speed Reference 7 14 CFW501 7...
Page 76: ...Available Motor Control Types 8 4 CFW501 8...
Page 108: ...Functions Common to all the Control Modes 11 14 CFW501 11...
Page 134: ...Digital and Analog Inputs and Outputs 12 26 CFW501 12...
Page 148: ...Faults and Alarms 14 12 CFW501 14...