Parâmetros de Leitura
CFW501 | 15-3
15
P0007 – Output Voltage
Adjustable
Range:
0 to 2000 V
Factory
Setting:
Properties:
ro
Access groups
via HMI:
READ
Description:
It indicates the line voltage in inverter output, in Volts (V).
P0009 – Motor Torque
Adjustable
Range:
-1000.0 % to 1000.0 %
Factory
Setting:
Properties:
ro
Access groups
via HMI:
READ
Description:
It indicates the torque developed by the motor in relation to the rated torque.
P0010 – Output Power
Adjustable
Range:
0.0 to 6553.5 kW
Factory
Setting:
Properties:
ro
Access groups
via HMI:
READ
Description:
It indicates the electric power in the inverter output. This power is determined through the formula:
P0010 = √3 x P0003 x P0007 x P0011.
Where:
P0003 is the output current measured;
P0007 is the reference output voltage (or estimated);
P0011 is the value of the cosine [(vector angle of the reference output voltage) – (vector angle of the output
current measured)].
P0011 – Cos
φ
on the Output
Adjustable
Range:
-1.00 to 1.00
Factory
Setting:
Properties:
ro
Access groups
via HMI:
READ
Description:
It indicates the power factor, that is, the relationship between the real power and the total power absorbed by
the motor.
Summary of Contents for CFW501 V1.8X
Page 2: ......
Page 8: ...Summary...
Page 34: ...General Information 2 4 CFW501 2...
Page 38: ...About the CFW501 3 4 CFW501 3...
Page 42: ...HMI and Basic Programming 4 4 CFW501 4...
Page 58: ...Identification of the Inverter Model and Accessories 6 4 CFW501 6...
Page 72: ...Logical Command and Speed Reference 7 14 CFW501 7...
Page 76: ...Available Motor Control Types 8 4 CFW501 8...
Page 108: ...Functions Common to all the Control Modes 11 14 CFW501 11...
Page 134: ...Digital and Analog Inputs and Outputs 12 26 CFW501 12...
Page 148: ...Faults and Alarms 14 12 CFW501 14...