Digital and Analog Inputs and Outputs
CFW501 | 12-19
12
d) DIRECTION OF ROTATION
If DIx is Inactive, the direction of rotation if clockwise; otherwise, the direction of rotation will be counterclockwise.
DIx
Time
Time
Inactive
Clockwise
Counterclockwise
Active
Output
speed
Figure 12.9:
Example of the direction of rotation function
e) LOCAL / REMOTE
If DIx is inactive, the local command is selected; otherwise, the remote command is selected.
f) JOG
The JOG command is the combination of the Run / Stop command with a speed reference via parameter P0122.
DIx -
Run-Stop
DIx -
General enable
Time
Time
Time
Inactive
Inactive
Active
Active
Output
speed
JOG speed
(P0122)
Acceleration
ramp
Deceleration
ramp
Time
Active
Inactive
DIx -
JOG
Figure 12.10:
Example of the JOG function