Digital and Analog Inputs and Outputs
CFW501 | 12-13
12
12.4 FREQUENCY OUTPUT
Like the frequency input is implemented in the digital input DI2, the frequency output is fixed to the transistor
digital output DO2.
The configuration and resources available in the frequency output are basically the same as those of analog
outputs, as shown in
Figure 12.5: Block diagram of the output in frequency FO (DO2) on page 12-13
.
Gain
FO – P0258
Function
FO – P0257
P0001
P0002
P0003
P0011
P0009
SoftPLC
P0037
P0696
P0697
P0698
Value FO
DO2
(*)
100
(%)
FO(%)
FO(%) – P0016
FO(Hz) – P0017
FO(Hz)
Calc. Hz/%
(Hz)
P0259 P0260
(*)
Control terminal available in the Plug-In module.
Figure 12.5:
Block diagram of the output in frequency FO (DO2)
P0016 – Frequency Output Value FO in %
Adjustable
Range:
0.0 to 100.0 %
Factory
Setting:
Properties:
ro
Access groups
via HMI:
READ, I/O
Description:
The percentage value of the output frequency FO. This value is given in relation to the range defined by P0259
and P0260.
P0017 – Frequency Output Value FO in Hz
Adjustable
Range:
0 to 20000 Hz
Factory
Setting:
Properties:
ro
Access groups
via HMI:
READ, I/O
Description:
The value in hertz of the output frequency FO.
Summary of Contents for CFW501 V1.8X
Page 2: ......
Page 8: ...Summary...
Page 34: ...General Information 2 4 CFW501 2...
Page 38: ...About the CFW501 3 4 CFW501 3...
Page 42: ...HMI and Basic Programming 4 4 CFW501 4...
Page 58: ...Identification of the Inverter Model and Accessories 6 4 CFW501 6...
Page 72: ...Logical Command and Speed Reference 7 14 CFW501 7...
Page 76: ...Available Motor Control Types 8 4 CFW501 8...
Page 108: ...Functions Common to all the Control Modes 11 14 CFW501 11...
Page 134: ...Digital and Analog Inputs and Outputs 12 26 CFW501 12...
Page 148: ...Faults and Alarms 14 12 CFW501 14...