3 Initial start-up
Power supply
3-8
Rev. 10 (06/2021)
USM Go
Charging the batteries
You can charge the lithium-ion batteries either directly
within the instrument or in an external charger.
Internal charging
If a lithium-ion battery is inserted, charging starts auto-
matically as soon as you connect the charger/power
adapter to the USM Go and to the mains power supply.
You can carry out ultrasonic tests and charge the batter-
ies at the same time.
The charging time is approx. ten hours with simultane-
ous ultrasonic testing. If the instrument is not used for ul-
trasonic testing, the charging time is approx. eight
hours. This charging time applies to ambient tempera-
tures of 25 … 30 °C.
Charging status
All battery charge controls and status updates are inter-
nal to the instrument. Updates are given at the upper
right corner of the display as described on the previous
page.
The charger/power adapter is a simple power supply
with no charging controls or intelligence. The LED on
the charger is a power indicator only and will show a
steady green light when AC power is provided at the in-
put.
External charging
You can charge lithium-ion batteries with an external
charger of the USM Go. Do not use any other chargers
for charging the lithium-ion batteries for the USM Go.
Summary of Contents for Krautkramer USM Go
Page 1: ...Krautkrämer USM Go USM Go Operating Manual Id No 49 155 Rev 10 06 2021 ...
Page 5: ...USM Go Rev 10 06 2021 0 5 Second operating level ...
Page 6: ...0 6 Rev 10 06 2021 USM Go Second operating level continued ...
Page 10: ...0 10 Rev 10 06 2021 USM Go ...
Page 20: ...0 10 Rev 10 06 2021 USM Go ...
Page 21: ...USM Go Rev 10 06 2021 1 1 Introduction 1 ...
Page 35: ...USM Go Rev 10 06 2021 2 1 Standard package and accessories 2 ...
Page 41: ...USM Go Rev 10 06 2021 3 1 Initial start up 3 ...
Page 53: ...USM Go Rev 10 06 2021 4 1 Principles of operation 4 ...
Page 76: ...4 Principles of operation Saving the settings 4 24 Rev 10 06 2021 USM Go ...
Page 77: ...USM Go Rev 10 06 2021 5 1 Operation 5 ...
Page 210: ...5 Operation Evaluation according to the DGS method 5 134 Rev 10 06 2021 USM Go ...
Page 211: ...USM Go Rev 10 06 2021 6 1 Documentation 6 ...
Page 240: ...6 30 Rev 10 06 2021 USM Go ...
Page 241: ...USM Go Rev 10 06 2021 7 1 Maintenance and care 7 ...
Page 247: ...USM Go Rev 10 06 2021 8 1 Interfaces and Peripherals 8 ...
Page 251: ...USM Go Rev 10 06 2021 9 1 Appendix 9 ...
Page 266: ...9 16 Rev 10 06 2021 USM Go ...
Page 267: ...USM Go Rev 10 06 2021 10 1 Specifications 10 ...
Page 278: ...10 12 Rev 10 06 2021 USM Go ...