4 - 30
Watkiss Automatic SpineMaster Service Manual - Edited 17/06/04
Service Procedures
•
Replacing Components
5. Remove both of the Cam Links. These are each held in place by two cir-
clips (see Figure 4:42).
6. Remove the two Paper Guides. Each Paper Guide is held in place by four
7. Undo the LH and RH Limit Sensor Mounts (253-859/860) from the Anvil.
Tie them out of the way.
8. Remove the Bolster Sensor Mount (253-349) from the Bolster.
9. Find the Connector Link in the Main Drive Chain and remove this Chain
10. Remove the Stop Assembly (907-404) from the machine by removing the
two M6 screws in the LH and RH Adjustment Supports (see Figure 4:44),
and remove the screws securing the LH and RH Stop Springs.
Figure 4:42 Cam Link - LH (Side Control Assembly
removed)
Circlips
Cam Link
Figure 4:43 Paper Guides
Paper Guides
Figure 4:44 Stop Assembly RH Mounting screws
M6 screws