2 - 2
Watkiss Automatic SpineMaster Service Manual - Edited 17/06/04
Status Indicator RAPs
•
Entry RAP
2.1 Entry RAP
Go to Error Indicator
Check the
Transformer Fuse
Check the F3 fuse
on PCB 900-141.
Does the Main Motor
rotate when a start
signal is present?
Check Wiring/
Motor.
Check Drive
Chains (see 4.8.7).
Is the Main Power
Switch illuminated?
Go to AC Mains
RAP (see 2.2).
Is the Error Indicator
Light illuminated?
Is the Stacker Sup-
port triggering the
Stacker Full Sensor?
Reset Stacker
Support.
Is LED1 on the Trans-
former Input PCB illu-
minated?
Does LED1 on PCB
900-141 illuminate
when a start signal
is present?
Is LED13 on PCB
900-197 flashing?
Yes
No
Yes
No
Yes
No
Yes
Replace PCB
900-197.
No
Yes
Yes
Yes
No
No
No