1 - 8
Watkiss Automatic SpineMaster Service Manual - Edited 17/06/04
Introduction
•
Routine Maintenance
Bypass Mode:
The booklets will bypass the SquareBacking process and will
be delivered straight to the stacker. The Book Diverter, activated by a sole-
noid, diverts the booklets directly to the stacker.
1.6.5 Error Indicator / Reset Button
This indicator/button performs several functions -
• A green light indicates an error. Correct the error and then press the
button to reset the ASM.
• The button can be used to start the machine if it is not automatically
started by hand-feeding or by connected equipment.
• When hand-feeding, the green light flashes as each booklet is proc-
essed. Another booklet can be inserted when the light goes out.
1.7 Routine Maintenance
Effective rountine maintenance helps prevent machine breakdowns and en-
sures that the SpineMaster delivers optimum performance.
Routine maintenance should only be conducted by technicians who have re-
ceived product-specific training.
The routine maintenance schedule sheet in this section may be photocopied for
this purpose and we recommend that a copy is kept for your records.
The normal service interval for the ASM is 12 months. This interval should be
reduced if the ASM is subject to heavy use.
Double Pass
Single Pass
SquareBack Mode
Bypass Mode
Error Indicator / Reset Button
Figure 1:10 Operating Modes