Service Procedures
•
Removing Components
Watkiss Automatic SpineMaster Service Manual - Edited 17/06/04
4
-
7
3. Unplug the Cassette Bus Cable from the Machine Interface PCB (900-
198) and unplug the Earth Cable from the Side Panel (see Figure 4:8).
4. Remove the two M4 Cap HD screws securing the Infeed Assembly (see
5. Lift and remove the Infeed Assembly (see Figure 4:10).
4.6.2 Removal of the Top Delivery Assembly
1. Switch off the power and disconnect the mains input lead.
2. Remove the Side Covers.
3. Remove the Top Delivery Assembly Cover.
Figure 4:8 Electrical Connections to the
Infeed Assembly
Bus
Earth
Divert Fingers
PARTS REQUIRED
TOOLS REQUIRED
None
3mm Allen Key
4mm Allen Key
Figure 4:9 Removing the Infeed Assembly
Infeed Assembly
M4 Cap HD screws
Figure 4:10 ASM with the Infeed Assembly removed