4 - 10
Watkiss Automatic SpineMaster Service Manual - Edited 17/06/04
Service Procedures
•
Machine Adjustments
WARNING
When operating the ASM with covers removed, be careful of moving compo-
nents and live circuits.
5. Unplug the main Drive Motor, unplug PL6 from PCB 900-197, and plug
in the Bypass Cable (740-294) (see Figure 4:15).
6. With the Stacker Assembly open, manually activate the Infeed Sensor to
start the ASM.
7. To cycle the carriage, manually activate the Clamp Optical Sensor.
8. Check the stop position of the Carriage. When viewed from above, the
centre-line of the trailing Carriage Cam Roller should align with the verti-
cal face of the Aluminium Side Plate (see Figure 4:17).
9. If the Carriage does not stop in the right place, adjust the Sensor again.
Check the end position of the Carriage at both ends of the Carriage Guide.
Figure 4:15 Unplugging the Main Drive Motor
Power to Main Drive Motor
Figure 4:16 Clamp Optical Sensor
Clamp Optical Sensor
Figure 4:17 Carriage Stop position (viewed
from Infeed Slot) - LH
Carriage Cam Roller
Bolster
Stop
Anvil
Aluminium Side Plate
(shown for position)