Sludge pump
●
Control cabinets including motor starters and monitoring
Fig 6-4
Fuel transfer and separating system (V76F6626F)
6.3.3.3
Separator feed pumps (1P02)
Feed pumps should be dimensioned for the actual fuel quality and recommended throughput
of the separator. The pump should be protected by a suction strainer (mesh size about 0.5
mm)
An approved system for control of the fuel feed rate to the separator is required.
MDF
HFO
Design data:
0.5 MPa (5 bar)
0.5 MPa (5 bar)
Design pressure
50°C
100°C
Design temperature
100 cSt
1000 cSt
Viscosity for dimensioning electric motor
6.3.3.4
Separator pre-heater (1E01)
The pre-heater is dimensioned according to the feed pump capacity and a given settling tank
temperature.