3.8
Wärtsilä 12V32, 750 rpm
ME
SCR
mode
DE
SCR
mode
AE
SCR
mode
ME
IMO
Tier 2
DE
IMO
Tier 2
AE
IMO
Tier 2
Wärtsilä 12V32
750
580
750
580
750
580
750
580
750
580
750
580
RPM
kW/cyl
Engine speed
Cylinder output
6960
6960
6960
6960
6960
6960
kW
Engine output
2.88
2.88
2.88
2.88
2.88
2.88
MPa
Mean effective pressure
Combustion air system (Note 1)
12.23
12.53
12.53
12.23
12.53
12.53
kg/s
Flow at 100% load
45
45
45
45
45
45
°C
Temperature at turbocharger intake, max.
55
55
55
55
55
55
°C
Air temperature after air cooler (TE 601)
Exhaust gas system (Note 2)
12.6
12.9
12.9
12.6
12.9
12.9
kg/s
Flow at 100% load
10.8
10.8
10.8
11.2
11.7
11.7
kg/s
Flow at 85% load
9.7
9.8
9.8
9.7
10.6
10.6
kg/s
Flow at 75% load
6.7
7.1
7.1
6.7
7.1
7.1
kg/s
Flow at 50% load
370
350
350
370
350
350
°C
Temperature after turbocharger, 100% load
(TE 517)
340
340
340
330
320
320
°C
Temperature after turbocharger, 85% load
(TE 517)
340
340
340
340
320
320
°C
Temperature after turbocharger, 75% load
(TE 517)
350
360
360
350
360
360
°C
Temperature after turbocharger, 50% load
(TE 517)
5.0
5.0
5.0
5.0
5.0
5.0
kPa
Backpressure, max.
911
908
908
911
908
908
mm
Calculated pipe diameter for 35m/s
Heat balance (Note 3)
880
898
898
880
898
898
kW
Jacket water, HT-circuit
1622
1598
1598
1622
1598
1598
kW
Charge air, HT-circuit
978
962
962
978
962
962
kW
Charge air, LT-circuit
792
810
810
792
810
810
kW
Lubricating oil, LT-circuit
220
220
220
220
220
220
kW
Radiation
Fuel system (Note 4)
700±50
700±50
700±50
700±50
700±50
700±50
kPa
Pressure before injection pumps (PT 101)
7.0
7.0
7.1
7.0
7.0
7.0
m
3
/h
Fuel flow to engine, approx.
16...24
16...24
16...24
16...24
16...24
16...24
cSt
HFO viscosity before engine
140
140
140
140
140
140
°C
HFO temperature before engine, max. (TE
101)
2.0
2.0
2.0
2.0
2.0
2.0
cSt
MDF viscosity, min
45
45
45
45
45
45
°C
MDF temperature before engine, max. (TE
101)
183
184
184
182
182
183
g/kWh
Fuel consumption at 100% load, HFO
182
184
184
179
181
182
g/kWh
Fuel consumption at 85% load, HFO
182
184
184
179
182
182
g/kWh
Fuel consumption at 75% load, HFO
184
189
194
181
187
192
g/kWh
Fuel consumption at 50% load, HFO
184
184
186
184
184
186
g/kWh
Fuel consumption at 100% load, MDF
3-24
Wärtsilä 32 Product Guide - a21 - 7 September 2016
Wärtsilä 32 Product Guide
3. Technical Data
Summary of Contents for WARTSILA32
Page 18: ...This page intentionally left blank...
Page 72: ...This page intentionally left blank...
Page 130: ...This page intentionally left blank...
Page 150: ...This page intentionally left blank...
Page 186: ...This page intentionally left blank...
Page 204: ...This page intentionally left blank...
Page 210: ...This page intentionally left blank...
Page 216: ...This page intentionally left blank...
Page 238: ...This page intentionally left blank...
Page 246: ...This page intentionally left blank...
Page 248: ...This page intentionally left blank...
Page 251: ......
Page 252: ......
Page 253: ......