3.10
Wärtsilä 16V32, 750 rpm
ME
SCR
mode
DE
SCR
mode
AE
SCR
mode
ME
IMO
Tier 2
DE
IMO
Tier 2
AE
IMO
Tier 2
Wärtsilä 16V32
750
580
750
580
750
580
750
580
750
580
750
580
RPM
kW/cyl
Engine speed
Cylinder output
9280
9280
9280
9280
9280
9280
kW
Engine output
2.88
2.88
2.88
2.88
2.88
2.88
MPa
Mean effective pressure
Combustion air system (Note 1)
16.21
16.81
16.81
16.21
16.81
16.81
kg/s
Flow at 100% load
45
45
45
45
45
45
°C
Temperature at turbocharger intake, max.
55
55
55
55
55
55
°C
Air temperature after air cooler (TE 601)
Exhaust gas system (Note 2)
16.7
17.3
17.3
16.7
17.3
17.3
kg/s
Flow at 100% load
14.9
14.4
14.4
14.9
15.6
15.6
kg/s
Flow at 85% load
13.0
13.1
13.1
13.0
14.2
14.2
kg/s
Flow at 75% load
9.0
9.5
9.5
9.0
9.5
9.5
kg/s
Flow at 50% load
370
350
350
370
350
350
°C
Temperature after turbocharger, 100% load
(TE 517)
330
340
340
330
320
320
°C
Temperature after turbocharger, 85% load
(TE 517)
340
340
340
340
320
320
°C
Temperature after turbocharger, 75% load
(TE 517)
350
360
360
350
360
360
°C
Temperature after turbocharger, 50% load
(TE 517)
5.0
5.0
5.0
5.0
5.0
5.0
kPa
Backpressure, max.
1049
1051
1051
1049
1051
1051
mm
Calculated pipe diameter for 35m/s
Heat balance (Note 3)
1173
1197
1197
1173
1197
1197
kW
Jacket water, HT-circuit
2163
2131
2131
2163
2131
2131
kW
Charge air, HT-circuit
1304
1283
1283
1304
1283
1283
kW
Charge air, LT-circuit
1056
1080
1080
1056
1080
1080
kW
Lubricating oil, LT-circuit
293
293
293
293
293
293
kW
Radiation
Fuel system (Note 4)
700±50
700±50
700±50
700±50
700±50
700±50
kPa
Pressure before injection pumps (PT 101)
9.4
9.4
9.4
9.3
9.3
9.5
m
3
/h
Fuel flow to engine, approx.
16...24
16...24
16...24
16...24
16...24
16...24
cSt
HFO viscosity before engine
140
140
140
140
140
140
°C
HFO temperature before engine, max. (TE
101)
2.0
2.0
2.0
2.0
2.0
2.0
cSt
MDF viscosity, min
45
45
45
45
45
45
°C
MDF temperature before engine, max. (TE
101)
183
184
184
182
182
185
g/kWh
Fuel consumption at 100% load, HFO
182
184
184
179
181
182
g/kWh
Fuel consumption at 85% load, HFO
182
184
184
179
182
182
g/kWh
Fuel consumption at 75% load, HFO
184
189
194
181
187
189
g/kWh
Fuel consumption at 50% load, HFO
184
184
186
184
184
186
g/kWh
Fuel consumption at 100% load, MDF
3-30
Wärtsilä 32 Product Guide - a21 - 7 September 2016
Wärtsilä 32 Product Guide
3. Technical Data
Summary of Contents for WARTSILA32
Page 18: ...This page intentionally left blank...
Page 72: ...This page intentionally left blank...
Page 130: ...This page intentionally left blank...
Page 150: ...This page intentionally left blank...
Page 186: ...This page intentionally left blank...
Page 204: ...This page intentionally left blank...
Page 210: ...This page intentionally left blank...
Page 216: ...This page intentionally left blank...
Page 238: ...This page intentionally left blank...
Page 246: ...This page intentionally left blank...
Page 248: ...This page intentionally left blank...
Page 251: ......
Page 252: ......
Page 253: ......