Fig 9-13
Preheating unit, electric (3V60L0562C).
Dimensions [mm]
Pipe conn.
Weight
[kg]
Pump capacity
[m³/h]
Heater capacity
[kW]
E
D
C
B
A
In/outlet
60 HZ
50 Hz
460
240
660
900
1250
DN40
95
13
11
18
480
290
700
720
1050
DN40
100
13
11
22.5
480
290
700
900
1250
DN40
103
13
12
27
480
290
700
720
1050
DN40
105
13
12
30
480
290
700
900
1250
DN40
125
13
12
36
510
350
755
720
1250
DN40
145
13
12
45
510
350
755
900
1250
DN40
150
13
12
54
550
400
805
900
1260
DN40
187
13
12
72
550
400
805
900
1260
DN40
190
13
12
81
575
450
855
900
1260
DN40
215
13
12
108
9.3.14
Throttles
Throttles (orifices) are to be installed in all by-pass lines to ensure balanced operating conditions
for temperature control valves. Throttles must also be installed wherever it is necessary to
balance the waterflow between alternate flow paths.
9.3.15
Thermometers and pressure gauges
Local thermometers should be installed wherever there is a temperature change, i.e. before
and after heat exchangers etc.
Local pressure gauges should be installed on the suction and discharge side of each pump.
Wärtsilä 32 Product Guide - a21 - 7 September 2016
9-19
9. Cooling Water System
Wärtsilä 32 Product Guide
Summary of Contents for WARTSILA32
Page 18: ...This page intentionally left blank...
Page 72: ...This page intentionally left blank...
Page 130: ...This page intentionally left blank...
Page 150: ...This page intentionally left blank...
Page 186: ...This page intentionally left blank...
Page 204: ...This page intentionally left blank...
Page 210: ...This page intentionally left blank...
Page 216: ...This page intentionally left blank...
Page 238: ...This page intentionally left blank...
Page 246: ...This page intentionally left blank...
Page 248: ...This page intentionally left blank...
Page 251: ......
Page 252: ......
Page 253: ......