Fig 9-5
Example diagram for single main engine (HFO), reduction gear fresh water
cooled (3V76C5262C)
System components:
Transfer pump
4P09
Heat recovery (evaporator)
4E03
Circulating pump (sea water)
4P11
Heater (preheating unit)
4E05
Circulating pump (LT)
4P15
Central cooler
4E08
Circulating pump (evaporator)
4P19
Cooler (reduction gear)
4E10
Air venting
4S01
Suction strainer (sea water)
4F01
Drain tank
4T04
Preheating unit
4N01
Expansion tank
4T05
Evaporator unit
4N02
Temperature control valve (heat recovery)
4V02
Stand-by pump (HT)
4P03
Temperature control valve (central cooler)
4V08
Circulating pump (preheater)
4P04
Stand-by pump (LT)
4P05
Pipe connections:
DN125
LT-water inlet
451
DN125
HT-water inlet
401
DN125
LT-water outlet
452
DN125
HT-water outlet
402
OD12
LT-water air vent from air cooler
454
OD12
HT-water air vent
404
DN125
LT-water from stand-by pump
457
DN32
Water from preheater to HT-circuit
406
OD12
LT-water air vent
483
DN125
HT-water from stand-by pump
408
OD12
HT-water airvent from air cooler
416
9-6
Wärtsilä 32 Product Guide - a21 - 7 September 2016
Wärtsilä 32 Product Guide
9. Cooling Water System
Summary of Contents for WARTSILA32
Page 18: ...This page intentionally left blank...
Page 72: ...This page intentionally left blank...
Page 130: ...This page intentionally left blank...
Page 150: ...This page intentionally left blank...
Page 186: ...This page intentionally left blank...
Page 204: ...This page intentionally left blank...
Page 210: ...This page intentionally left blank...
Page 216: ...This page intentionally left blank...
Page 238: ...This page intentionally left blank...
Page 246: ...This page intentionally left blank...
Page 248: ...This page intentionally left blank...
Page 251: ......
Page 252: ......
Page 253: ......