11.3.7.4
Conventional exhaust gas silencer (5R02)
Yard/designer should take into account that unfavourable layout of the exhaust system (length
of straight parts in the exhaust system) might cause amplification of the exhaust noise between
engine outlet and the silencer. Hence the attenuation of the silencer does not give any absolute
guarantee for the noise level after the silencer.
When included in the scope of supply, the standard silencer is of the absorption type, equipped
with a spark arrester. It is also provided with a soot collector and a condense drain, but it
comes without mounting brackets and insulation. The silencer can be mounted either
horizontally or vertically.
The noise attenuation of the standard silencer is either 25 or 35 dB(A). This attenuation is valid
up to a flow velocity of max. 40 m/s.
Fig 11-11
Exhaust gas silencer (3V49E0142c)
Table 11-1
Typical dimensions of exhaust gas silencers
Attenuation: 35 dB(A)
Attenuation: 25 dB(A)
B
A
D
NS
Weight [kg]
L
Weight [kg]
L
1310
5260
980
4010
260
635
1300
600
1910
6050
1470
4550
270
745
1500
700
2490
6340
1930
4840
280
840
1700
800
2900
6870
2295
5360
290
860
1800
900
3730
7620
2900
5880
330
870
1900
1000
Flanges: DIN 2501
11-12
Wärtsilä 32 Product Guide - a21 - 7 September 2016
Wärtsilä 32 Product Guide
11. Exhaust Gas System
Summary of Contents for WARTSILA32
Page 18: ...This page intentionally left blank...
Page 72: ...This page intentionally left blank...
Page 130: ...This page intentionally left blank...
Page 150: ...This page intentionally left blank...
Page 186: ...This page intentionally left blank...
Page 204: ...This page intentionally left blank...
Page 210: ...This page intentionally left blank...
Page 216: ...This page intentionally left blank...
Page 238: ...This page intentionally left blank...
Page 246: ...This page intentionally left blank...
Page 248: ...This page intentionally left blank...
Page 251: ......
Page 252: ......
Page 253: ......