12.
Turbocharger Cleaning
Regular water cleaning of the turbine and the compressor reduces the formation of deposits
and extends the time between overhauls. Fresh water is injected into the turbocharger during
operation. Additives, solvents or salt water must not be used and the cleaning instructions in
the operation manual must be carefully followed.
12.1
Turbine cleaning system
A dosing unit consisting of a flow meter and an adjustable throttle valve is delivered for each
installation. The dosing unit is installed in the engine room and connected to the engine with
a detachable rubber hose. The rubber hose is connected with quick couplings and the length
of the hose is normally 10 m. One dosing unit can be used for several engines.
Water supply:
Fresh water
0.3 MPa (3 bar)
Min. pressure
2 MPa (20 bar)
Max. pressure
80 °C
Max. temperature
15-30 l/min (depending on cylinder configuration)
Flow
The turbocharges are cleaned one at a time on V-engines.
Fig 12-1
Turbocharger cleaning system (4V76A2937a)
Size
Pipe connections
System components
OD18
Cleaning water to turbine
502
Dosing unit with shut-off valve
01
OD18
Cleaning water to compressor
509
Rubber hose
02
Wärtsilä 32 Product Guide - a21 - 7 September 2016
12-1
12. Turbocharger Cleaning
Wärtsilä 32 Product Guide
Summary of Contents for WARTSILA32
Page 18: ...This page intentionally left blank...
Page 72: ...This page intentionally left blank...
Page 130: ...This page intentionally left blank...
Page 150: ...This page intentionally left blank...
Page 186: ...This page intentionally left blank...
Page 204: ...This page intentionally left blank...
Page 210: ...This page intentionally left blank...
Page 216: ...This page intentionally left blank...
Page 238: ...This page intentionally left blank...
Page 246: ...This page intentionally left blank...
Page 248: ...This page intentionally left blank...
Page 251: ......
Page 252: ......
Page 253: ......