![W&T 57630 Manual Download Page 17](http://html1.mh-extra.com/html/wandt/57630/57630_manual_3082028017.webp)
17
W&T
Assigning the IP address
Subject to errors and modifications:
assigns IP address 172.17.232.17, subnet mask 255.255.255.0
and gateway 172.17.232.252 to the Web-IO.
IP no.+<ENTER>:
<- Web-IO
172.17.232.17,255.255.255.0,172.17.232.252
-> Web-IO
172.17.232.17,255.255.255.0,172.17.232.252-1
<- Web-IO
2.3.2 Serial deactivation of the DHCP-/BOOTP client
The DHCP-/BOOTP function of the Web-IO can be turned off
while serially assigning the IP address. We recommend doing
this in any case where the IP assignment will not be expressly
performed using DHCP/BOOTP.
To deactivate the DHCP/BOOTP client, enter the option „-0“
(zero) immediately following the IP address (no spaces!) and
finish the entry with <
Enter
>.
Example:
xxx
-> Web-IO
IP no.+<ENTER>:
<- Web-IO
172.17.232.17,255.255.255.0,172.17.232.252-0
-> Web-IO
172.17.232.17,255.255.255.0,172.17.232.252-0
<- Web-IO
This of course functions the same way when entering the
subnet mask and gateway..
You can reactivate the function at any time later by using Web-
Based Management im the browser.
Menu item: