W&T
Time / Date
6.1
Time / Date - Setting
The Web-IO 12+12 Digital has an internal clock with date
functions.
6.1.1 Time zones
m
Required access rights:
Administrator
The Web-IO uses Greenwich Time (GMT) internally, which is used
as a general time base all over the World. The local time deviates
from GMT depending on the time zone you are in. The time in
Germany is GMT + 1h (in winter), the time in the United States
is GMT - 5h, etc.
If the Web-IO will be used in another time zone, the offset can be
adjusted accordingly.
To do this, go to
Config >> Device >> Time/Date >> TimeZone:
GMToffset
Enter here the difference between local and GMT time in the
format hh.mm. A sign can also be used in the entry field („+“ or „-
“).
Enable
To activate, check Apply Timezone to use the entered offset value.
Send the settings to the Web-IO by clicking on the
Temporary
Storage
button.