124
W&T
Box-to-Box
5.7.3 GetBox-to-Box connection status
m
Required access rights:
Administrator
The connection status of a Box-to-Box connection can be obtained
from the navigation tree under
Diag >> Test >> Output Config
.
Here you are shown which operation mode the individual outputs
are working in. Additionally the current status of a Box-to-Box
connection is displayed at the bottom of the Web page.
5.7.4 Stopping Box-to-Box mode
Box-to-Box Modus only by Master
m
Required access rights:
Administrator
Stopping Box-to-Box mode should always be done using the
corresponding configuration of the master. The master and slave
Web-IO must be connected on the network. Select in the
navigation tree of the master :
Config >> Device >> Basic Settings
>> Binary1 >> TCP Client
and delete the entry for
Server IP Addr
.
Also set
Application Mode
to
Default.
Confirm by clicking on the
Temporary Storage
button
.
Then under
Config >> Device >> Basic Settings >> Binary1 >>
set the
Operation Mode
to
TCP Server .
Confirm by clicking on the
Temporary Storage
button
.