108
wallaceperimetersecurity.com
Phone: 866.300.1110
INSTALLER MENU FUNCTIONS
Table 6. SmartDC Controller - Installer Menu Functions
Ref.
No�
Installer Menu
Setting Options
(
Bold
= Factory Settings)
Menu Tasks and Explanations
Associated
DC Controller
Connections
Display
10
DG 0 (OFF)
DUAL GATE
0 = solo operator
1 = Secondary unit
2 = Primary unit
3 = Sally Port A
4 = Sally Port B
Configures gate operator as a Primary
or as a Secondary (or a Sally Port
configuration) in a dual-gate installation.
When you assign one unit as Primary (or
Sally Port A), you must configure the other
as Secondary (or Sally Port B) through
the Installer Menu. See
Secondary Menu Setup” on page 136
Note: Use a 2-pair, twisted, shielded
cable with one pair of wires used to
connect A-A and B-B terminals between
the two boards. The other pair will
connect the Common terminals. The
shield should then be grounded on one
end to one of the operators.
Shielded
cable to DUAL
GATE input
terminals.
Connect Dual
Gate COM
(Gate 1) to
Dual Gate
COM (Gate 2).
Pair wires:
A – A, COM
– COM, and
B – B.
11
SG 0 (OFF)
SEQUENCED GATE
0 = solo operator
1 = Loop View #1
2 = Loop View #2
3 = Loop View #3
4 = Loop View #4
Establishes communication after wiring
two or more gate operators as sequential
gates. This menu item only appears if the
Dual Gate (DG) is set to 0 (solo operator).
See note in above cell.
Note: After selecting SG settings,
consider accessing the User Menu in each
gate operator to address the Close Timer
(CT) setting.
Shielded
cable to DUAL
GATE input
terminals
on both
operators. Pair
wires:
A – A, COM
– COM, and
B – B.
12
CH 0 (AC)
CHARGER TYPE
0 = AC powered charger
1 = solar powered charger
Assigns charger type.
Note: If a solar-powered unit is ordered
and delivered factory-ready, this menu
item will not appear.
(N/A)
13
BT 0 (STANDARD)
BATTERY TYPE
0 = standard (8Ah)
1 = extended (50Ah)
2 = maximum (110Ah)
Assign the battery type used by the
operator.
Note: Smaller batteries are charged with
less current to avoid overheating and
larger batteries are charged with more
current to supply a more rapid change.
Extended
(50Ah)
batteries
require wire
extensions
and shelf
installation.
Maximum
(110Ah)
batteries
require
separate
housing and
wiring.