162
wallaceperimetersecurity.com
Phone: 866.300.1110
TROUBLESHOOTING
Table 12. SmartDC Controller - Troubleshooting
Ref.
No�
Display
Description
Possible Causes
Solutions
Condition
Alert, Error or Fault
46
ERROR 8
RPM SENSOR
RPM sensor
disconnected.
Motor Encoder or wires are
damaged or unplugged.
Check wiring from the motor
to the SmartDC Controller
board.
47
ERROR 9
BATTERY
DISCONNECT
The SmartDC Controller
detected there is no
battery connected.
The batteries are
disconnected, or a wiring
fault exists. Kinetic
operators ship with a wire
disconnected to prevent
battery drain.
Replaced by Alert 28 in
h5.57 software version for
AC powered operators.
1. Ensure the red wire in the
upper left corner of the
control box is connected to
the switch.
2. Correct any losses with
battery wiring.
3. Check the 35-amp fuse on
the circuit board.
48
ERROR 10
SLOWDOWN
SWITCH
Not used in Kinetic
operators.
N/A
N/A